Natural Gas Analysis
Recently, natural gas has been recognized as a clean resournce for energy, in addition to being a raw material for chemical products. Recently a cutting-edge drilling technology has increased the use of shale gas. As the production area diversifies, the need for gas composition analysis has increased. Shimadzu addresses analytical requests with a wide system GC lineup. For analysis of liquified gas, such as LPG, a dedicated injector with a vaporizer is available. Both manual injection and online injection are available. The operation software can automatically calculate needed values, such as indexes, calorific values, etc.
Natural Gas Analysis System Lineup
Model Name | Nexis GC-2030 BIDUFNGA | Nexis GC-2030FNGA-II1 | Nexis GC-2030FNGA-II2 | Nexis GC-2030FNGA1 | Nexis GC-2030FNGA2 |
Reference Method | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 |
Type of Detector | BID, FID | TCDx2, FID | TCD, FID | TCDx2, FID | TCD, FID |
Target Compounds | Permanent gases, C1-C5, H2S, C6+(backflush) | H2, O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush) | O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush) | He, H2, O2, N2, CO, CO2, H2S, C1-C5, C6+ (backflush) | O2, N2, CO, CO2, H2S, C1-C5, C6+ (backflush) |
Analysis Time | 5 minutes | 10 minutes | 10 minutes | 10 minutes | 10 minutes |
Others | Permanent gases>10 ppm, H2S>100 ppm, CH4>100 ppm, Other hydrocarbons>10 ppm, Calorific value software available |
Permanent gases>100 ppm, H2S>1000 ppm, CH4>20%, Other hydrocarbons>10 ppm, Calorific value software available |
Permanent gases> 100 ppm, H2S>1000 ppm, CH4>20%, Other hydrocarbons>10 ppm, Calorific value software available |
Permanent gases>50 ppm, H2S>500 ppm, Hydrocarbons>10 ppm, Calorific value software available |
Permanent gases>50 ppm, H2S>500 ppm, Hydrocarbons>10 ppm, Calorific value software available |
Application Datasheet | Download |
Download |
Download |
Download |
Download |
Model Name | Nexis GC-2030ENGA1 | Nexis GC-2030ENGA2 | Nexis GC-2030NGA1 | Nexis GC-2030NGA2 | Nexis GC-2030HNR1 | Nexis GC-2030HNR2 |
Reference Method | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588 | - | - |
Type of Detector | TCDx2, FID | TCDx2, FID | TCD | TCD | FID | FID |
Target Compounds | He, H2, O2, N2, CO, CO2, H2S, C1-C14 | H2, O2, N2, CO, CO2, H2S, C1-C18 | He, H2, O2, N2, CO, CO2, H2S, C1-C5 (Better He and H2 separation) |
O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush) | C1-C5 C6+(backflush) | C1-C5 C6+(backflush) |
Analysis Time | 30 minutes | 28 minutes | 23 minutes | 23 minutes | 27 minutes | 10 minutes |
Others | Permanent gases>50 ppm, H2S>500 ppm, Hydrocarbons>10 ppm, Liquified samples can be directly injected. |
Permanent gases>50 ppm, H2S>500 ppm, Hydrocarbons>10 ppm, Liquified samples can be directly injected. |
- | - | C1 is 0.01%,C2-C6 is 0.001% Packed column as main column | Hydrocarbons > 0.001% Good separation |
Application Datasheet | Download |
Download |
Download |
Download |
Download |
Download |
LPG Analysis System Lineup
Model Name | Nexis GC-2030LPGHC1 | Nexis GC-2030LPGHC2 | Nexis GC-2030DFC1 |
Type of Detector | FID | FID | FID x2 |
Target Compounds | 10 ppm for hydrocarbon C1-C6 | 10 ppm for hydrocarbon C1-C6 | 0.1 ppm to 90% for C1-C5, 0.1 ppm to 10% for Methanol, 0.1 ppm to 10% for Ethanol |
Analysis Time | 15 minutes | 15 minutes | 11 minutes |
Others | LPG is vaporized by on-line vaporizer device. | Liquid sample is measured by internal sample loop in the liquid sampling device. | Analysis of methanol and ethanol in LPG |
Application Datasheet | Download |
Download |
Download |
GC-2014 system is also available for some applications.
News / Events
-
COA Search for SH Series GC Columns is now available
A Certificate of Analysis (COA) is a document that ensures the product meets the shipping requirements. COA Search for SH Series GC Columns has been released.
-
Artificial Photosynthesis Content has been Updated
Artificial photosynthesis is a technique to capture energy from the sun and store it chemically. It is expected to become the 4th renewable energy source along with photovoltaic, solar thermal, and biomass. Clink this link and the latest application is now available.
-
Shimadzu GC Driver for Waters Empower has been released
Waters Empower chromatography data systems can now be used to control AOC-30 autoinjectors in Shimadzu Nexis™ GC-2030 systems and perform packed column analysis. Space-saving AOC-30 systems offer reliable and long-term performance, and support capillary/packed column analysis using only a single GC-2030 system.
-
Greenhouse Gas Analysis
The greenhouse gas analyzer is a gas chromatography system that can simultaneously measure CH4, CO2, and N2O gases in a single sample injection, an analysis that was difficult to achieve with previous systems. Equipped with a robust high-throughput syringe injection system for processing up to 108 sample vials, this analyzer is designed to support research related to reducing greenhouse gas levels.
-
Three Analytical and Measuring Instruments Win the Internationally Recognized “iF Design Award 2024”
The Shimadzu LCMS-2050 high-performance liquid chromatograph mass spectrometer, the Brevis GC-2050 gas chromatograph, and the ICPMS-2040/2050 ICP mass spectrometer won the internationally recognized iF Design Award 2024 in the product design category.
-
ELEM-SPOT, Element Selective Gas Chromatograph Mass Spectrometer has been released
Shimadzu’s unique ELEM-SPOT system is the world’s first Gas Chromatograph Mass Spectrometer (GC-MS) with an element-selective combustion unit (EL-30) included for selectively analyzing nitrogen-containing compounds or oxygenated compounds in complex hydrocarbon compounds with high sensitivity.