Shim-pack Velox C18
HPLC Column
C18
Shim-pack Velox C18 is a traditional end-capped C18-bonded phase which offers the highest hydrophobic retention of any Shim-pack Velox phases and is applicable to a wide range of applications such as pharmaceutical, food, environmental and clinical and neutrals at moderately low and mid-range pH.
- General purpose column for reversed-phase chromatography
- Highest hydrophobic retention among Shim-pack Velox series
- Compatible with moderately acidic to neutral mobile phases (pH 2-8)
Method Transfer for Cyanocobalamin Analysis within the USP Allowable Adjustment
The assay of cyanocobalamin (a synthetic form of vitamin B12) with 5 μm fully-porous ODS column described in the USP monograph is transferred to a new method with Shim-pack Velox C18 2.7 μm column, within USP allowable adjustments. Analytical time and solvent consumption can be saved with transferred methods while meeting the requirements of system suitability.
Column | L/dp | Flow rate (mL/min) |
N | System suitability test result (Requirement: %RSD < 2.0 %) |
---|---|---|---|---|
VP-ODS (5 μm, 4.6 x 150 mm) |
30,000 | 0.50 | 5,244 | tR: 0.025 % Area: 0.175 % (n=6) |
Velox C18
(2.7 μm, 4.6 x 100 mm) |
37,037
(+23 %) |
0.50 | 9,497 (+81 %) |
tR: 0.035 % Area: 0.103 % (n=6) |
0.93 | 4,466 (-15 %) |
tR: 0.084 % Area: 0.220 % (n=6) |
News / Events
-
Ion Chromatography Solutions for Environmental Analysis
Shimadzu has focused on the development of instruments for environmental analysis for decades, helping scientists to detect, identify and quantify trace-level pollutants and meet environmental testing demands, for both regulatory purposes and to advance Research & Development.
-
Shimadzu has released the Peakintelligence™ for LC
Liquid chromatography is now an indispensable analytical technique used in pharmaceutical, food, and a wide variety of other industries. In these industries, there is a need for efficient data analysis methods that are not user-dependent. Peakintelligence for LC software includes AI algorithm* that was developed by learning expert peak integration skills.
-
Oxygen heterocyclic compounds profile evaluation in cold-pressed Citrus essential oils using supercritical fluid chromatography coupled to photodiode array detector
A large number of analytical techniques to characterize the non-volatile composition of Citrus essential oils (EOs) were introduced in the literature. However, the reports of Citrus EOs analysis by supercritical fluid chromatography (SFC) with UV or mass spectrometry detectors for the analysis of non-volatile polar compounds are still few.
-
Shimadzu has released the Shim-pack Mix-HILIC, Chromatography Column for Hydrophilic Interactions
Comprehensive Analysis of Hydrophilic Metabolites in Metabolomics
-
A new video has been released -Finding Out What Makes Things Sour-
Ever wondered what makes some foods sour? In this video we explore that question while also introducing one of Japan's traditional sour foods!
-
New Nexera FV
Nexera FV and LabSolutions™ FV together form a new UHPLC system capable of monitoring flow synthesis and batch synthesis reactions, and automating formulation dissolution testing.