Language
EspaƱol
English
0

    NSA-308 - Specs

    Continuous Gas Analyzer in Flue Gas

    NSA-308

    Measurement method

    NOx, SO2, CO, CO2: Nondispersive infrared absorption method
    O2: Magnetic wind method

    Measurement range

    NOx: 0-200 to 0-2500 ppm
    SO2: 0-100 to 0-2500 ppm
    CO: 0-100 to 0-5000 ppm
    CO2: 0-5 to 0-20 vol%
    O2: 0-10 to 0-25 vol%

    Size

    Approx. 830 (W) x 765 (D) x 1805 (H) mm

    Weight

    Approx. 300 kg

    Power supply

    100 VAC, approx. 1 KVA

    Read more
    Show Less

    NSA-308

    Measurement method

    Non-dispersive infrared ray absorption method (ratio photometry) O2: Magnetic wind method

    Measurement range

    It differs depending on the components measured, so inquire for details.