Language
Español
English
0

    Type 1

    Applications

    Combusion Equipment Test / Research

    Transmission Output

    0-1 V DC, 3-channel insulated output (non-insulated between channels)

    Sample Gas Conditions(Note 3)

    At the CGT-7100 main unit inletPressure: -980 to +980 PaTemperature: Ambient temperature
    Dust: 0.1 g/Nm3 max.
    Composition: N2 : 70 vol% min.; SO3 : Not contained; H2 O: Below the saturation point at ambient temperature

    External drain separator

    Yes

    Weight (Main unit)

    Approx. 16 kg

    Dimensions

    W260 x H452 x D420 mm (Excluding protrusions)

    Power Requirements

    110 V, 115 V, 120 V, 127 V, 220 V, 230 V, 240 V AC, 50-60 Hz, max. 150 VA

    Permitted Ambient Temperature

    5-40°C. Should be protected from direct sunlight and radiant heat.

    Data Storage toExternal Media (Note 2)

    Allows data in CSV format to be saved to a USB flash drive.

    Wireless Signal Output (Note 2)

    Yes

    Display

    LCD. Allows a simultaneous display of 3 items.

    Measured Components

    CO, CO2

    Sample Gas Flow Rate

    Approx. 2.5 L/min (The gas flow rate for the sample cell is 1.0 L/min.)

    Response Time (Note 1)

    CO, CO2, CH4: Selectable from 15, 30, or 60 seconds

    Linearity

    Within ±2% of full scale

    Span Drift

    Within ±1% of full scale per day

    Zero Drift

    Within ±1% of full scale per day

    Repeatability

    Within ±0.5% of full scale

    Measurement principle

    CO, CO2, CH4: Single light source dual beam non-dispersive infrared absorption method
    (ratio photometry)

    Measurement range

    CO: 0 to 1000/5000 ppm
    CO2: 0 to 5/ 15 vol%

    External Signal Input

    0-1 V DC, 1 channel, signal input from an external analyzer, display

    Note 1: Response time is measured from the point the gas enters the sample gas inlet until 90% response is indicated (flow line purge time plus electrical system response time).
    Note 2: The smart devices and USB flash drives on which operation has been validated are shown below in "Operation Validated."
    Note 3: If conditions are not satisfied, contact a Shimadzu representative. If a mist absorber set (option) is used, then an SO3 mist can be used up to about 30 ppm. If the concentration of a component other than N2 is 30 vol% or more, then measurement specifications might not be satisfied in some cases.

    Read more
    Show Less

    Type 2

    Applications

    Fuel Cell Research

    Transmission Output

    0-1 V DC, 3-channel insulated output (non-insulated between channels)

    Sample Gas Conditions(Note 3)

    At the CGT-7100 main unit inletPressure: -980 to +980 PaTemperature: Ambient temperature
    Dust: 0.1 g/Nm3 max.
    Composition: N2 : 70 vol% min.; SO3 : Not contained; H2 O: Below the saturation point at ambient temperature

    External drain separator

    No

    Weight (Main unit)

    Approx. 16 kg

    Dimensions

    W260 x H452 x D420 mm (Excluding protrusions)

    Power Requirements

    110 V, 115 V, 120 V, 127 V, 220 V, 230 V, 240 V AC, 50-60 Hz, max. 150 VA

    Permitted Ambient Temperature

    5-40°C. Should be protected from direct sunlight and radiant heat.

    Data Storage toExternal Media (Note 2)

    Allows data in CSV format to be saved to a USB flash drive.

    Wireless Signal Output (Note 2)

    Yes

    Display

    LCD. Allows a simultaneous display of 3 items.

    Measured Components

    CO, CH4

    Sample Gas Flow Rate

    Approx. 2.5 L/min (The gas flow rate for the sample cell is 1.0 L/min.)

    Response Time (Note 1)

    CO, CO2, CH4: Selectable from 15, 30, or 60 seconds

    Linearity

    CO: Within ±2% of full scaleCH4: Within ±3% of full scale

    Span Drift

    Within ±1% of full scale per day

    Zero Drift

    Within ±1% of full scale per day

    Repeatability

    Within ±0.5% of full scale

    Measurement principle

    CO, CO2, CH4: Single light source dual beam non-dispersive infrared absorption method
    (ratio photometry)

    Measurement range

    CO: 0 to 5 vol%
    CH4: 0 to 20 vol%

    External Signal Input

    0-1 V DC, 1 channel, signal input from an external analyzer, display

    Read more
    Show Less

    Type 3

    Applications

    Catalyst Research

    Transmission Output

    0-1 V DC, 3-channel insulated output (non-insulated between channels)

    Sample Gas Conditions(Note 3)

    At the CGT-7100 main unit inletPressure: -980 to +980 PaTemperature: Ambient temperature
    Dust: 0.1 g/Nm3 max.
    Composition: N2 : 70 vol% min.; SO3 : Not contained; H2 O: Below the saturation point at ambient temperature

    External drain separator

    No

    Weight (Main unit)

    Approx. 16 kg

    Dimensions

    W260 x H452 x D420 mm (Excluding protrusions)

    Power Requirements

    110 V, 115 V, 120 V, 127 V, 220 V, 230 V, 240 V AC, 50-60 Hz, max. 150 VA

    Permitted Ambient Temperature

    5-40°C. Should be protected from direct sunlight and radiant heat.

    Data Storage toExternal Media (Note 2)

    Allows data in CSV format to be saved to a USB flash drive.

    Wireless Signal Output (Note 2)

    Yes

    Display

    LCD. Allows a simultaneous display of 3 items.

    Measured Components

    CO, CO2

    Sample Gas Flow Rate

    100 to 400 mL/min (variable)

    Response Time (Note 1)

    Less than 3 minutes(at a sample gas flow rate of 100 mL/min)

    Linearity

    Within ±2% of full scale

    Span Drift

    Within ±1% of full scale per day

    Zero Drift

    Within ±1% of full scale per day

    Repeatability

    Within ±0.5% of full scale

    Measurement principle

    CO, CO2, CH4: Single light source dual beam non-dispersive infrared absorption method
    (ratio photometry)

    Measurement range

    CO: 0 to 10/20 vol%
    CO2: 0 to 10/20 vol%

    External Signal Input

    0-1 V DC, 1 channel, signal input from an external analyzer, display

    Read more
    Show Less

    Type 1

    Type

    CO-CO2 analyzer for measuring exhaust gases from combustion

    Measurement range

    CO: 0-100 ppm to 0 -100 vol%
    CO2: 0-1,000 ppm to 0-100 vol%
    CH4: 0-200 ppm to 0-100 vol%
    O2: 0 to 5/10/25 vol% (optional)

    Repeatability

    Within ±0.5 % of full scale

    Weight

    Approx. 16 kg

    Read more
    Show Less

    Type 2

    Type

    CO-CH4 analyzer for fuel cell research

    Measurement range

    CO: 0-100 ppm to 0 -100 vol%
    CO2: 0-1,000 ppm to 0-100 vol%
    CH4: 0-200 ppm to 0-100 vol%
    O2: 0 to 5/10/25 vol% (optional)

    Repeatability

    Within ±0.5 % of full scale

    Weight

    Approx. 16 kg

    Read more
    Show Less

    Type 3

    Type

    CO-CO2 analyzer for catalyst research (small flow rate type)

    Measurement range

    CO: 0-100 ppm to 0 -100 vol%
    CO2: 0-1,000 ppm to 0-100 vol%
    CH4: 0-200 ppm to 0-100 vol%
    O2: 0 to 5/10/25 vol% (optional)

    Repeatability

    Within ±0.5 % of full scale

    Weight

    Approx. 16 kg

    Read more
    Show Less