Language
Español
English
0

    ICPMS-2040 Series / ICPMS-2050 Series - Options

    Inductively Coupled Plasma Mass Spectrometry

    LabSolutions™ ICPMS Ver. 2

    The new version of LabSolutions ICPMS software displays all necessary information in a single window, simplifying operation for new users. Experienced users can utilize advanced configurable settings for challenging applications, in-depth research and all analyses in between.

    LA-ICP-MS Software

    By combining this software with ICPMS-2040/2050 connected to a laser ablation instrument, sample measurement and data output in a format compatible with imaging data analysis software are possible. 

    Peripheral Equipment

     

    AS-20 Autosampler

    AS-20 Autosampler

    The autosampler has 60 15-mL and 8 50-mL vial positions. The rotary design allows for shorter sample introduction times and can reduce memory effects.

    • Rotary Type Minimizes probe tube length

      Rotary Type
      (Minimizes probe tube length)

    • XY-Table Type

      XY-Table Type
      (A longer tube length is required to reach the furthest vial)

     

    ASX-560 Autosampler

    ASX-560 Autosampler

    ASX-560 holds 240 14-mL vials and 10 50-mL vials for standards. By replacing the standard rack with a rack sold separately, 160 20-mL vials or 84 50-mL vials can be held. 
    Note: Requires a separate ASX connection kit for ICPMS.

    ASX-280 Autosampler

    ASX-280 Autosampler

    ASX-280 holds 120 14-mL vials and 10 50-mL vials for standards. By replacing the standard rack with a rack sold separately, 80 20-mL vials or 42 50-mL vials can be held.
    Note: Requires a separate ASX connection kit for ICPMS.

    Online Internal Standard Kit

    Online Internal Standard Kit

    This kit is used for in-line mixing of sample and internal standard solution and introducing the mixture into the nebulizer.

    Dual Valve Unit

    Dual Valve Unit

    This is used to automatically switch between multiple solutions, such as pure water, instrument tuning solution, internal standard solution and cleaning solution.
    Note: Requires a separate AC adapter and power cord.

    HFS-6 Hydrofluoric Acid Sample Injection System

    This system is used to directly introduce samples that contain hydrofluoric acid. Fluoropolymer materials are used in the nebulizer, chamber, and drain system, whereas alumina is used in the injector unit on the torch.

    Organic Solvent Injection System

    For analysis of organic solvents, a gas mixture of 70% argon and 30% oxygen is introduced into the torch to prevent precipitation of carbon (C) from organic solvents. This system includes a gas controller for mixed gases, a quadruple torch for organic solvents, and pump tubing for organic solvents (for ethanol/methanol/IPA).

    Cyclone Chamber, Quartz

    This chamber is used to analyze trace boron, which is challenging to analyze using a standard borosilicate glass chamber.

    Standard Torch Kit

    This kit includes a torch with a 1.8 mm injector bore diameter that supports a 1.6 kW high-frequency output as well as a compatible shield screen, bonnet, and adapter.

    3rd Gas Introduction Unit

    This gas controller unit is for using a 10 % ammonia and 90 % helium gas mixture as the reaction gas in an ICPMS-2050 system.

    Water Bubbler

    This is used to humidify argon gas and prevent clogging of the torch and nebulizer when analyzing high TDS samples.

    LC Connection Kit

    This connection kit is required for configuring an LC-ICP-MS system that combines an ICPMS-2040/2050 Series system with a Nexera inert series or Prominence inert analysis system. For information about compatible LC systems, contact Shimadzu.

    LabSolutions ICPMS TRM

    This software is for controlling Shimadzu LC and ICPMS-2040/2050 Series systems and analyzing chromatography data.

    LC-ICP-MS Method Package

    Optimized analytical methods for the Shimadzu LC-ICP-MS system are provided as method files, so there is no need for users to develop their own methods. There are three types available: ‘Method Package for Mercury Speciation Analysis’, ‘Method Package for Arsenic Speciation Analysis Type 1’, and ‘Method Package for Arsenic Speciation Analysis Type 2’. 

     

    Related Files

     

    Do you live in the United States?

    Please visit our US website.