OPTIC-4
Multimode Inlet for Gas Chromatograph-Mass Spectrometer
High-Performance Multimode Inlet
A Next-Generation Inlet Accommodating a Variety of Sample Forms
Equipped with injection modes capable of accommodating a wide range of sample forms, the OPTIC-4 is the ultimate inlet in GC-MS sample injection systems. Attaching the OPTIC-4 to the AOC-6000 Plus draws out its very best performance.
The wide range of injection modes offered by the OPTIC-4 multimode inlet makes it possible to accommodate many different sample forms. So, in addition to split/splitless injections, many other analyses, such as the pyrolysis analysis of solid samples and the thermal desorption analysis of odor components, can be performed.
Simplifying Pretreatment—DMI
(Difficult Matrix Introduction)
With DMI, a microvial containing the sample is inserted in the liner, and the liner is then heated at the injection port before analyzing the sample. By adjusting the temperature of the injection port, non-volatile impurity components are left remaining in the microvial, enabling GC/MS measurements to be performed with a minimal amount of pretreatment.
After Trapping/Concentration Using MonoTrap™,
Thermal Desorption Provides High-Sensitivity Analysis
By using the MonoTrap*, which has a silica monolith structure and a high trapping efficiency, to trap volatile components in the sample, then using the OPTIC-4 for thermal desorption, analyses requiring higher sensitivity can be performed. Moreover, the high-speed heating function provides for rapid desorption of the trapped components, which results in acquisition of sharper peaks.
The liner placed in the rack, after removing its caps at the CDC station, is installed in the OPTIC-4 injection port.
* For further information on the MonoTrap, refer to the website of GL Sciences, Inc.
Sharper Peaks, Enhanced Separation
Due to a sample introduction path of only 1 cm, and the adoption of a high-speed heating system capable of 60 °C /s, sharper peaks are realized.
There is only 1 cm between the sample and the tip of the analysis column. For this reason, the system is ideal for analysis of compounds with high adsorptivity or degradability.
Peaks are made sharper by attaching a cryo-trap (option) to the GC oven. Samples trapped by the cryo-trap are heated rapidly, up to 60 °C/s, so the development of bands is kept to a minimum.
Intuitive Operation Using Dedicated Evolution Workstation Software
The dedicated Evolution Workstation software for the OPTIC-4 displays analysis conditions in a time chart for intuitive grasping and modification, enabling easy formulation of conditions. Optimization is easy, since methods accommodating various injection modes have been included.
Wide Variety of Injection Modes
The various injection modes allow analysis of many different sample forms.
Liner | Sample Introduction Method | Application Examples |
DMI | Thermal extraction | Content of 1,4-dioxane in shampoo |
MonoTrap TD | Thermal desorption | Odor from Clothing |
MonoTrap TD | Thermal desorption | Odor from product |
DMI | Pyrolysis | Pyrolysis of resin |
DMI | Reactive Pyrolysis | Reactive Pyrolysis of Resin |
Solid adsorption agent (TD) | Thermal desorption | Atmospheric gas in automobile |
DMI | Thermal extraction | Reactive Pyrolysis of Resin |
MonoTrap TD | Thermal desorption | Aroma from Food Products |
News / Events
-
Automatic Derivatization System for Phenethylamine Drugs
This system allows the on-column derivatization using auto-injector AOC-30i and a LabSolutions GCMS system that is now equipped with 2-step injection. On-column derivatization allows for the direct analysis of extracted urine samples without additional sample pretreatment, which can significantly shorten the time required for derivatization.
-
New Webinar Information -Redefine Volatile and Semivolatile Organic Compounds Analysis by GC-MS, from Start to Finish-
In this webinar, we will explore how Shimadzu’s latest GC-MS instruments, in combination with the multi-platform software LabSolutions and LabSolutions Insight, enable successful detection, quantitation, and suspect screening of VOCs and SVOCs. Plus, discover how these tools support EPA methods, from initial sample analysis to final data reporting.
-
AOAC INTERNATIONAL Posters are now available.
-
Shimadzu has released the GCMS-QP2050
The next-generation GCMS-QP2050 gas chromatograph mass spectrometer, with its accumulation of impressive Shimadzu technology, will lead the way forward. New value is provided by hardware boasting astounding reliability and stability, and easy-to-operate software equipped with superior automated technology.
-
Solutions for Analysis of Ethylene Oxide and 2-Chloroethanol in Food
Even though Ethylene oxide (EtO / EO) is well-known to be a toxic compound with carcinogenic and mutagenic concerns, it has been widely used for fumigation in the food industry because it effectively reduces or eliminates microbiological contamination with bacteria/fungi. The recent recall of food products exported to the EU due to non-compliance with EU regulations has highlighted the importance of quantitation of EtO and 2-CE residues in food.
-
Latest issue of Shimadzu Journal, featuring Forensics / Toxicology, has come out.
This issue focuses on "Forensics / Toxicology", an area where science and technology are particularly important and needed. It starts with two customer interviews.