Language
Español
English
0

    Compact without Compromise

    Space-saving yet expandable design

    • The compact Brevis GC-2050, with a 350 mm system width, including an auto-injector (AOC™-30i), makes even more use of lab space. Compared to the flagship Nexis™ GC-2030, the system's width has been reduced by approximately 35 %. At the same time, it is possible to connect additional headspace samplers, a mass spectrometer, and other accessories (available soon), providing the scalability to cover the analytical needs of today's GC/GCMS users.
    • Space-saving yet expandable design

     

    Sufficient GC oven size

    • Despite its space-saving design, this GC oven does not require a dedicated column, and up to two general capillary columns can be used.
    • Sufficient GC oven s ize

     

    Remote Display

    • Even without a monitor on the Brevis GC-2050, you can use the GC Remote Display installed on a PC or tablet to monitor the device status and perform operations.

      Note: Only one Remote Display can be connected to a single GC at a time.
      Connection Method: LAN / USB cable.

    • Remote Display

     

    Compact and easy to maintain

    Compact and easy to maintain

     

    ①One-touch inlet maintenance

    The injection port can be opened or closed without tools by simply sliding the ClickTek™ Nut lever. Replace the insert, slide the lever, and feel the click to ensure leak-free performance.

     

    ②Fast inlet maintenance, Easy sTop

    Clicking the Maint. (Maintenance) button on the GC front will start lowering the temperature of the GC inlet and oven, and stop the gas supply automatically*. After maintenance of the inlet, clicking the button again will return the instrument to standby after an automatic leak check. Routine maintenance procedures can be further simplified.

    Note: Disabling the automatic gas supply shutdown to protect the MS detector is possible.

    Fast inlet maintenance, Easy sTop

     

    ③Tool-less column installation

    The ClickTek makes column attachment a one-touch operation. A noticeable clicking sensation signals a secure column connection, putting the user at ease.

    Note: The ClickTek connector is optional.

     

    Less Energy and Gas Consumption

    ECO design

    The Brevis GC-2050 consumes 30 % less power than conventional GCs. It also minimizes helium usage and supports operations with alternative carrier gases.

    • Comparison of power consumption on a GC run cycle.

      Comparison of power consumption on a GC run cycle.
      *Comparisons were made under the following analytical conditions.SPL: 270℃, FID: 270℃,
      Oven: 50℃ → (10℃/min)→250℃(10min Hold)→(Cooling)→50℃
      *The amount of electricity consumed will vary depending on the laboratory environment.

    • High-performance insulating materials and a smaller oven have eliminated heat loss. As a result, the Brevis GC-2050 achieves about a 30 % reduction in power consumption during analysis compared to conventional GCs.

     

    Safer and even faster analysis with H2 gas

    • High-speed analysis of impurities in benzene using hydrogen carrier gas

      High-speed analysis of impurities in benzene using hydrogen carrier gas

    • Safer and even faster analysis with H2 gas

     

    •  
      The Brevis GC-2050 can be equipped with a hydrogen sensor. Not only does it enable early detection of potential leaks in the oven and maintain a safe standby mode, but if a hydrogen leak occurs, it turns off the main power to prevent an accident. In addition, the GC main unit has an automatic carrier gas leak check function that supports the use of hydrogen carrier gas. Furthermore, a gas selector* can switch the carrier gas to nitrogen after an analysis has been completed to enhance safety. Hydrogen carrier gas enables fast analysis (application example above) and maximizes throughput in the laboratory.

      * Hydrogen sensor and gas selector are options.

    • Safer and even faster analysis with H2 gas

    Built-in Analytical Intelligence

    Automatic remote operation

    • With Remote Display and LabSolutions™ Direct, GC systems can be accessed from anywhere with a smart device or a PC, dramatically improving the analysis workflow and enabling new ways of working.
    • Automatic remote operation

     

    Automating the Procedures of Experienced Analysts, Clean Pilot ANALYTICAL INTELLIGENCE

    • Baselines can be unstable during GC startup. The Clean Pilot feature provides quick and efficient automatic conditioning to provide stable analytical results while reducing the burden on laboratory personnel.
    • Automating the Procedures of Experienced Analysts, Clean Pilot

     

    Analysis Starts Immediately under the Optimal Conditions, Automatic Start and Stop Function

    The Brevis GC-2050 automatically performs gas and temperature control, allowing the system to shut down and start up unattended. When not performing analysis, the system can be shut down to reduce unnecessary power and gas consumption, thereby reducing running costs.

    Analysis Starts Immediately under the Optimal Conditions, Automatic Start and Stop Function

     

    Supply Gas Check ANALYTICAL INTELLIGENCE

    • When connecting a main and a spare gas cylinder to the gas selector (option), the gas selector will monitor the main gas cylinder pressure and automatically switch the gas supply to the backup line when the cylinder becomes empty. This prevents problems before they occur and allows you to continue analysis with peace of mind.
    • Supply Gas Check

     

    Enabling Remote Control and Monitoring, LabSolutions Direct

    • Remote Control
    • Remote operation and monitoring

      LabSolutions Direct, a standard feature of LabSolutions, allows you to monitor instrument status and chromatographic signals, start and stop the instrument, and start the analysis from a web browser on a PC or smart device at a remote location.

     

    Making Routine Analysis More Convenient

    2D Code Navigation

    When a smart device reads the code or clicks the URL link on a PC, a solution, including procedures or videos, is presented for a quick recovery.

    2D Code Navigation

    Best-in-Class Performance

    Outstanding Analytical Reproducibility

    The Brevis GC-2050 provides best-in-class analytical precision. The latest auto-injector, AOC-30i, enables continuous analysis with a high level of precision that cannot be achieved with manual operation. In addition, the flow controller (AFC) with a built-in CPU supports constant linear velocity, constant flow rate, and constant pressure control of carrier gas to achieve outstanding analytical reproducibility with ultra-high speed and ultra-precise control.

    • Continuous analysis of the Grob Test Mixture

      Continuous analysis of the Grob Test Mixture

    • Outstanding Analytical Reproducibility