LC/MS/MS Method Package for Water Quality Analysis
For LabSolutions™ LCMS Software
Ready-to-Use Methods Provided
Shimadzu provides method files, including pre-registered MRM parameters with optimized quantitative and reference ions, LC separation parameters, and retention times and peak identification parameters for each compound, as well as report templates for outputting quantitation results, as a package. If retention times are adjusted when the system is introduced, based on the HPLC configuration delivered, the analysis process can be started as soon as the specified columns, mobile phases, and standard samples are supplied.
Smooth Analysis of Multiple Analytes with LabSolutions Insight
When analyzing data for multiple components and analytes, everything from batch analysis to the creation of reports can be performed by LabSolutions Insight. LabSolutions Insight is a software program equipped with quantitative analysis and screening functions. In the analysis window, information is displayed for each target compound and set of measurement data, and both quantitative values and area values can be listed. This allows the user to select the easiest display method for checking the data in accordance with the workflow. In addition, by using the flagging function, only the results exceeding specified standard values are displayed, improving the analytical throughput of multiple components and analytes subject to the regulations.
Methods Easily Customized
Since LabSolutions Version 5 enables the addition or deletion of components to be analyzed, methods can be easily customized. In addition, the package includes a compound parameter list enables the creation of new tables that list only the components needed.
Compounds List
Golf Course Pesticides: 44 compounds
HPLC Conditions
- Analytical column : Shim-pack XR-ODSII (150 mmL. × 2.0 mmI.D., 2.2μm)P/N 228-41623-93
- Mobile phase A : 5 mmol / L Ammonium acetate - Water
- Mobile phase B : 5 mmol / L Ammonium acetate - Methanol
- Flow rate : 0.2 mL / min
- Injection volume : 5 μL
- Column temperature : 40 °C
Step | Time(min) | A(%) | B(%) |
---|---|---|---|
0 | 0 | 80 | 20 |
1 | 13 | 10 | 90 |
2 | 23 | 10 | 90 |
3 | 23.01 | 80 | 20 |
4 | 28 | 80 | 20 |
Compound Name
Acetamiprid Azoxystrobin Bensulide Boscalid Butamifos Cafenstrole Cafenstrole metabolite Clothianidin Cumyluron Cyclosulfamron Cyproconazole Diazinon Difenoconazole Dithiopyr Ethoxysulfron |
Fenitrothion Flazasulfuron Flutolanil Harosulfuron-methyl Imidacloprid Iprodione Isoprothiolane Isoxathion Mecoprop Mepronil Metalaxyl Oxaziclomefone Pencycuron Pendimethalin Propiconazole |
Propyzamide Pyributicarb Siduron Simazine Simeconazole Tebuconazole Tebufenozide Terbucarb Tetraconazol Thiamethoxam Thifluzamide Triclopyr Triflumizole Triflumizole metabolite |
Pesticides Targeted for Water Quality Control: 32 compounds
HPLC Conditions
- Analytical column : L-Column ODS (150 mmL. × 2.1 mmI.D., 5μm)
- Mobile phase A : 0.1% formic acid - Water
- Mobile phase B : Acetonitrile
- Flow rate : 0.2 mL / min
- Injection volume : 10 μL
- Column temperature : 40 °C
Step | Time(min) | A(%) | B(%) |
---|---|---|---|
0 | 0 | 100 | 0 |
1 | 30 | 0 | 100 |
2 | 35 | 0 | 100 |
3 | 35.01 | 100 | 0 |
4 | 45 | 100 | 0 |
Compound Name
2,4-D Asulam Azoxystrobin Bensulfuron-methyl Bensulid(SAP) Bentazone Carbaryl(NAC) Carbofuran Carpropamid Diuron(DCMU) Dymuron |
Fipronil Flazasulfuron Halosulfuron-methyl Iprodione MBC Mecoprop(MCPP) Methomyl MPP MPP oxon MPP oxon sulfone MPP oxon sulfoxide |
MPP sulfone MPP sulfoxide Probenazole Siduron Simazine(CAT) Thiobencarb Thiodicarb Thiuram Triclopyr Tricyclazole |
Remarks and Precautions
- LabSolutions LCMS Ver. 5.42 SP2 or later is required.
- Shimadzu makes no warranty regarding the accuracy of information included in the database or the usefulness of information obtained from using the database.
- Be sure to perform tests using standard samples to confirm qualitative and quantitative information obtained with the given system.
- To reliably identify registered substances using this database, measure samples using the instrument parameters specified in the method template files included in the product.
News / Events
-
New High Resolution Accurate Mass Library for Forensic Toxicology
Perform forensic toxicology screening for drugs of abuse, psychotropic drugs, pharmaceuticals, pesticides, and natural toxins using this high-resolution accurate mass database.
-
Shimadzu has released the Shim-vial™ H glass, S glass.
Shimadzu provides high-quality vials that thoroughly eliminate these risks by visually inspecting each vial, allowing them to be used with confidence.
-
INTERNATIONAL MASS SPECTROMETRY CONFERENCE 2024
Visit the Shimadzu booth at the International Mass Spectrometry Conference (IMSC) 2024.
-
Metabolomics 2024
Shimadzu Lunch Presentation at Metabolomics 2024
Date: junio 20th, 2024 (Thursday)
Time: 12:25 – 1:25 p.m. -
New LabSolutions Insight Biologics
Supporting Innovation with Oligonucleotide Therapeutics
-
Shimadzu has released the LCMS-TQ RX Series High-Performance Liquid Chromatograph Mass Spectrometers
Innovative technology, exceptional design and new ways of thinking are part of our engineering DNA delivering solutions for the ever-changing needs of any laboratory. As our scientific and business needs change our engineering design evolves and adapts. The result is the RX Series of triple quadrupole LC-MS instruments designed with unmatched capability, redefined reliability and creating a new standard in actionable data.