AccuSpot
Nano Spotter for MALDI-TOF MS
Bringing LC to MALDI Technology LC/MS/MS is often regarded as the technique of choice in identifying components from complex mixtures; however, it is not without its limitations. An alternative approach is to consider LC/MALDI.
LC/MALDI has a number of advantages in that the LC is decoupled from the MALDI mass spectrometer.
MALDI can support:
- A higher data acquisition at the top of the eluting peak (owing to the fact that the peak can be spread over several spots) allows a precise selection of precursor ions for MS/MS analysis.
- Sample archiving (the MALDI plate can be stored and used to further validate protein identification if required)
- Uncompromised sensitivity (LC/MALDI analysis can focus solely on the peak apex) Increased depth of coverage of the sample and enhanced sequence coverage for the detected proteins.
The AccuSpot was designed for online collection of fractions eluting from Capillary/Nano LC.
- Supports micro-fractionation on Shimadzu MALDI-TOF/MS targets, for 96 or 384 well, and ABI format MALDI plates.
- Multiple plates can be spotted continuously. The plate changer allows a maximum of 9 Shimadzu (MTP format) or 18 ABI plates to be spotted without stopping.
- Matrix solution is added automatically. Depending on the application, matrix solution can be mixed with the column eluent via a "T" prior to the probe or at the probe tip through a 3 duct system. The third duct is used for rinsing the probe tip.
- Easy to use software gives the user total control over the spotting operation from setting matrix flow rate to spotting pattern to report generation.
- The system includes a CCD camera as a standard accessory, so the actual spotting activity and status can be confirmed on the PC screen.
- An optional barcode reader is available for sample tracking.
- Compatible with any HPLC system capable of delivering micro/capillary/nanoflow.
The AccuSpot automates LC micro-fractionation, spotting and preparation for MS analysis. With the AccuSpot system, LC eluent can be accurately and continuously spotted onto target plates, in trace amounts (eg.50nL). This allows for automatic preparation of target plates for MALDI-TOF-MS measurements. When used in conjunction with Shimadzu's Two-Dimensional Micro LC System and Shimadzu Biotech's AXIMA MALDI-TOF instruments, proteome analysis can be performed with a higher degree of precision and with greater sequence coverage.
AccuSpot applications
Features
-
Unique sample spotting mode
The "Half-Contact" spotting method (see above) uses plate sensors (patent pending) to...
Applications
Documents | Date Creation Date |
---|---|
2011-10-17 |
Technical Documents
News / Events
-
INTERNATIONAL MASS SPECTROMETRY CONFERENCE 2024
Visit the Shimadzu booth at the International Mass Spectrometry Conference (IMSC) 2024.
-
Maldi EasyCare Training Video has been uploaded.
The Shimadzu MALDI EasyCare solution offers a convenient way to perform routine maintenance on your system and increase your uptime. Manual cleaning of ion optics is safe, quick (period from venting to ion optics removal is approx. 10 mins), easy-to-do requiring no tools (except single-point use of flat blade screwdriver) and no technical expertise due to full guidance by software wizard. All cleaning materials provided.
-
Shimadzu has released the MALDI-EasyCare, Upgrade for the MALDI-8000 Series MALDI-TOF mass spectrometers
Maintain optimal performance of your system using MALDI EasyCare to manually clean the ion optics and autotune the instrument.
-
Shimadzu has released the FlexiFocus™
The FlexiFocus adaptor has been specifically designed to hold a FlexiFocus insert and position it optimally for analysis in the Shimadzu MALDI-8020 and MALDI-8030 benchtop MALDI-TOF instruments.
-
Latest issue of Shimadzu Journal, featuring Forensics / Toxicology, has come out.
This issue focuses on "Forensics / Toxicology", an area where science and technology are particularly important and needed. It starts with two customer interviews.
-
Life Science Biomarker Industry Page has been updated
Biomarkers are derived from living organisms and found in tissues, blood, and other bodily fluids. Biomarkers are indicators of biological changes in an organism and are used to diagnose disease, in prognosis, and to evaluate the efficacy and safety of pharmaceuticals. Biomarkers can be nucleic acids, proteins, peptides, lipids, and sugars, and are identified using various “omics” techniques.