0

    HITS-X Series - Options

    High-Speed Impact Testing Machines

    (Optional) Force Detectors and Applicable Grips

    Force Detector and Grip for Flat Plate Samples

    Force Detector

    Model SHL-10 kN-P
    Part number 346-77909-01
    Capacity Maximum 10 kN (tensile)
     

    High-Speed Grip for Flat Plate Samples

    Model High-speed grip for flat plate samples
    Part number 346-77160-02
    Capacity Maximum 10 kN (tensile)
    Shape of Grip Wedge shape: W 13 mm, H 15 mm, file teeth
    Applicable Sample Flat plate: Width max.
    13 mm, thickness 0.5 to 3 mm
     

    Load detector and grips for round rods

    The grips for small rods can be attached to the force detector.
    Note: Please contact us for manufacture of a different shape of specimens and grips.
    Note: Different sizes can also be accommodated.

    Grips for high-speed testing of round rods

    Model Round rod grips for high-speed tensile testing
    Part number 346-77184-01
    Capacity Maximum 10 kN (tension)
    Shape of Grip M12 × 1.5 female threads
    Applicable
    Sample
    Round rod specimens with M12 × 1.5 threaded ends
    (threaded length of 20 mm or more)

    Optional Accessories Striker, Clamping Plates

    Striker (with load detector)

     

    Main striker unit and tip

    Model name Striker ø12.7 Striker ø20 Striker ø10
    Part No.
    for main unit
    339-83665-02 339-83665-03 339-83665-01
    Part No.
    for tip
    347-40060-06 347-40062-09 347-41604-00
    Capacity (puncture) 10kN 10 kN 10 kN
    Striker diameter ø12.7 mm ø20 mm ø10 mm
    Related Standards ASTM D 7363 ISO 6603-2 ISO 6603-2

    Note: Striker units with other load capacities and shapes are supplied as options.

    Clamping Plates

    Clamping plates

    Part number 346-77213-02 346-77213-01 346-77213-03
    Hole diameter ø76 mm ø40 mm ø100 mm
    Related Standards ASTM ISO ISO
    Applicable specimen size ☐100mm
    t = 1 to 3 mm
    ☐60mm
    t = 1 to 3 mm
    ☐140mm
    t = 1 to 3 mm

    Examples of striker-clamp combinations for specific standards

    Related Standards ISO 6603-2 ISO 6603-2 ASTM D 3763
    Striker diameter ø20.0 mm ø10.0 mm ø12.7 mm
    Clamping plates ø140 mm ø100 mm ø176 mm
    Remarks Standard
    combination
    For fragile materials
    or low fracture strain
    -

    Note: Non-standards combinations are supplied as options.

     

    Using an Optional Thermostatic Chamber
    Acquire Data for Temperature-Dependent High-Speed Behavior

    A thermostatic chamber (-40 to +150 °C) can be used to obtain temperature-dependent data for high-speed behavior.

    Layout Diagram (same for HITS-PX and HITS-TX)

    Install the main testing machine on the ground floor, on a concrete floor at least 200 mm thick (able to withstand 1500 kg). The machine includes springs and other measures to isolate vibration, but avoid installing the machine in locations prone to transmitting vibrations.

    Do you live in the United States?