    Microservo MMT Series - Specs

    Magnetic Micro Testing System

    MMT-500NV-10

    Test Force

    ±500N

    Piston stroke

    ±10mm

    Cycle speed

    100Hz

    Controlled items

    Test force and stroke (two can be added as options)

    Indication accuracy : Test force

    Within ±0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater

    Indication accuracy : Stroke

    Within +1 % of indicated value or ±0.1 % of maximum stroke, whichever is greater

    Installation space (W × D × H)

    Approx. 1000 × 500 × 1200 mm

    Actuator mount

    Either top or bottom mount

    Total weight

    Approx. 150 kg

    Power Requirements

    1Ø 100V 1kVA

    Site requirements

    - Minimal temperature variations (+10 to +40 ℃ recommended, with temperature variations within ±5 ℃)
    - Low humidity
    - Not exposed to direct air flow from heating or cooling systems
    - No direct sunlight
    - Low dust
    - No significant vibration

    Read more
    Show Less

    MMT-250NV-10

    Test Force

    ±250N

    Piston stroke

    ±10mm

    Cycle speed

    100Hz

    Controlled items

    Test force and stroke (two can be added as options)

    Indication accuracy : Test force

    Within ±0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater

    Indication accuracy : Stroke

    Within +1 % of indicated value or ±0.1 % of maximum stroke, whichever is greater

    Installation space (W × D × H)

    Approx. 1000 × 500 × 1200 mm

    Actuator mount

    Either top or bottom mount

    Total weight

    Approx. 120 kg

    Power Requirements

    1Ø 100V 1kVA

    Site requirements

    - Minimal temperature variations (+10 to +40 ℃ recommended, with temperature variations within ±5 ℃)
    - Low humidity
    - Not exposed to direct air flow from heating or cooling systems
    - No direct sunlight
    - Low dust
    - No significant vibration

    Read more
    Show Less

    Test Force

    ±100N

    Piston stroke

    ±10mm

    Cycle speed

    100Hz

    Controlled items

    Test force and stroke (two can be added as options)

    Indication accuracy : Test force

    Within ±0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater

    Indication accuracy : Stroke

    Within +1 % of indicated value or ±0.1 % of maximum stroke, whichever is greater

    Installation space (W × D × H)

    Approx. 1000 × 500 × 1200 mm

    Actuator mount

    Either top or bottom mount

    Total weight

    Approx. 100 kg

    Power Requirements

    1Ø 100V 1kVA

    Site requirements

    - Minimal temperature variations (+10 to +40 ℃ recommended, with temperature variations within ±5 ℃)
    - Low humidity
    - Not exposed to direct air flow from heating or cooling systems
    - No direct sunlight
    - Low dust
    - No significant vibration

    Read more
    Show Less

    MMT-101NV-2

    Test Force

    ±100N

    Piston stroke

    ±2mm

    Cycle speed

    100Hz

    Controlled items

    Test force and stroke (two can be added as options)

    Indication accuracy : Test force

    Within ±0.5 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater

    Indication accuracy : Stroke

    Within +1 % of indicated value or ±0.1 % of maximum stroke, whichever is greater

    Installation space (W × D × H)

    Approx. 1000 × 500 × 1200 mm

    Actuator mount

    Either top or bottom mount

    Total weight

    Approx. 100 kg

    Power Requirements

    1Ø 100V 1kVA

    Site requirements

    - Minimal temperature variations (+10 to +40 ℃ recommended, with temperature variations within ±5 ℃)
    - Low humidity
    - Not exposed to direct air flow from heating or cooling systems
    - No direct sunlight
    - Low dust
    - No significant vibration

    Read more
    Show Less

    MMT-11NV-2

    Test Force

    ±10N

    Piston stroke

    ±2mm

    Cycle speed

    60Hz

    Controlled items

    Test force and stroke (two can be added as options)

    Indication accuracy : Test force

    Within ±1 % of indicated value or ±0.02 % of maximum dynamic test force, whichever is greater

    Indication accuracy : Stroke

    Within +1 % of indicated value or ±0.1 % of maximum stroke, whichever is greater

    Installation space (W × D × H)

    Approx. 1000 × 500 × 1200 mm

    Actuator mount

    Bottom

    Total weight

    Approx. 80 kg

    Power Requirements

    1Ø 100V 500VA

    Site requirements

    - Minimal temperature variations (+10 to +40 ℃ recommended, with temperature variations within ±5 ℃)
    - Low humidity
    - Not exposed to direct air flow from heating or cooling systems
    - No direct sunlight
    - Low dust
    - No significant vibration

    Read more
    Show Less

    MMT11NV-2

    Test force capacity

    ±10 N

    Stroke

    ±2 mm

    Max. frequency

    60 Hz

    Power Requirements

    AC100 V

    Read more
    Show Less

    -101NV-10

    Test force capacity

    ±100 N

    Stroke

    ±10 mm

    Max. frequency

    60 Hz

    Power Requirements

    AC100 V

    Read more
    Show Less

    -250NV-10

    Test force capacity

    ±250 N

    Stroke

    ±10 mm

    Max. frequency

    60 Hz

    Power Requirements

    AC100 V

    Read more
    Show Less
    English