English
Español
English
0

    SSG-H Series - Specs

    One-Touch, Strain Gauge Extensometers

    SSG25-50H

    Types and main specifications

    Part No

    346-56752-13

    Gauge length (mm)

    25

    Applicable
    sample dNote2
    Maximum (mm) : Rod

    ø10

    Applicable
    sample dNote2
    Maximum (mm) : Flat plate

    W15 x T10

    Precision

    ISO 9513/JIS B7741 Class 0.5
    Measurement range up to 0.3 mm: within ±1.5 μm
    Measurement range above 0.3 mm: within ±0.5 % of indicated value

    Guaranteed precision range

    Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

    Weight (g)

    Approx. 64

    Operational temp.
    range

    5 to 40 °C

    Power Requirements

    When using the ESA type amplifier: Single-phase 100 V AC 150 VA

    Note 1: The case where an amplifier with a range switching function is used is shown.
    Note 2: Not applicable to thin films, thin plates or fine wires.

    Read more
    Show Less

    SSG25-100H

    Types and main specifications

    Part No

    346-56752-14

    Gauge length (mm)

    25

    Applicable
    sample dNote2
    Maximum (mm) : Rod

    ø10

    Applicable
    sample dNote2
    Maximum (mm) : Flat plate

    W15 x T10

    Precision

    ISO 9513/JIS B7741 Class 0.5
    Measurement range up to 0.3 mm: within ±1.5 μm
    Measurement range above 0.3 mm: within ±0.5 % of indicated value

    Guaranteed precision range

    Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

    Weight (g)

    Approx. 72

    Operational temp.
    range

    5 to 40 °C

    Power Requirements

    When using the ESA type amplifier: Single-phase 100 V AC 150 VA

    Read more
    Show Less

    SSG50-10H

    Types and main specifications

    Part No

    346-56752-21

    Gauge length (mm)

    50

    Applicable
    sample dNote2
    Maximum (mm) : Rod

    ø15

    Applicable
    sample dNote2
    Maximum (mm) : Flat plate

    W25 x T14

    Precision

    ISO 9513/JIS B7741 Class 0.5
    Measurement range up to 0.3 mm: within ±1.5 μm
    Measurement range above 0.3 mm: within ±0.5 % of indicated value

    Guaranteed precision range

    Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

    Weight (g)

    Approx. 70

    Operational temp.
    range

    5 to 40 °C

    Power Requirements

    When using the ESA type amplifier: Single-phase 100 V AC 150 VA

    Read more
    Show Less

    SSG50-10SH*

    Types and main specifications

    Part No

    346-56752-26

    Gauge length (mm)

    50

    Applicable
    sample dNote2
    Maximum (mm) : Rod

    ø15

    Applicable
    sample dNote2
    Maximum (mm) : Flat plate

    W25 x T14

    Precision

    JIS K7161 measurement range
    Up to 200 μm: Accuracy ±1 μm
    Measurement range above 200 μm: within ±0.5 % of
    indicated value

    Guaranteed precision range

    Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

    Weight (g)

    Approx. 70

    Operational temp.
    range

    5 to 40 °C

    Power Requirements

    When using the ESA type amplifier: Single-phase 100 V AC 150 VA

    Read more
    Show Less

    SSG75-6SHAD

    Types and main specifications

    Part No

    346-56752-30

    Gauge length (mm)

    75, 50 variable type

    Applicable
    sample dNote2
    Maximum (mm) : Rod

    ø15

    Applicable
    sample dNote2
    Maximum (mm) : Flat plate

    W25 x T14

    Precision

    JIS K7161 measurement range
    Up to 200 μm: Accuracy ±1 μm
    Measurement range above 200 μm: within ±0.5 % of
    indicated value

    Guaranteed precision range

    Usage temperature: 18 to 28 °C, fluctuation: Within ±2 °C

    Weight (g)

    Approx. 105

    Operational temp.
    range

    5 to 40 °C

    Power Requirements

    When using the ESA type amplifier: Single-phase 100 V AC 150 VA

    Read more
    Show Less

    Do you live in the United States?