    UV-2600i, UV-2700i - Applications

    UV-VIS-NIR Spectrophotometer

    Applications

    Applications Date Creation Date

    2024-01-23

    2023-10-24

    2023-10-24

    2022-10-24

    2022-09-28

    2022-06-28

    2022-06-01

    2021-11-26

    2021-11-01

    2021-06-29

    2020-08-04

    2020-05-15

    2020-03-25

    2020-03-05

    2017-10-30

    2017-10-26

    2017-04-03

    2016-08-31

    2015-07-07

    2014-08-01

    2013-10-25

    2013-08-08

    2013-03-24

    2012-07-26

    2012-06-26

    2012-02-06

    2012-01-27

    Read more
    Show Less
    adobe

    Most of the documents on the LITERATURE is available in PDF format. You will need Adobe Acrobat Reader to open and read PDF documents. If you do not already have Acrobat Reader, you can download it free at the Adobe's Website. Click the GET ADOBE READER icon on the left to download a free copy of Adobe Acrobat Reader.

    Electricity, Electronics, and Optics

    Band Gap Measurements for Compound Semiconductors

    Band Gap Measurements for Compound Semiconductors

    The diffuse reflection spectra for two types of compound semiconductors (red line: Culn0.5Ga0.5Se2, blue line: CulnSe2) used as solar cell materials have been measured using the ISR-2600Plus integrating sphere. It is evident that the absorption edge (position where the reflectance drops) differs depending on the sample. This difference signifies a difference in the band gap* for these samples. (The samples were provided by Wada Laboratory, Faculty of Science and Technology, Ryukoku University.) The band gaps for the samples were calculated utilizing the Tauc method. The results obtained were 1.27 eV for Culn0.5Ga0.5Se2 (red line) and 0.99 eV for CulnSe2 (blue line). * The term band gap refers to the energy difference between the top of the valence band, which is full of electrons, and the bottom of the conduction band, which does not contain electrons.

    Construction

    Window Glass Transmission Measurements

    Window Glass Transmission Measurements

    Two types of window glass were measured utilizing the ISR-2600Plus integrating sphere. The sample shown by the red line is highly transparent to near-infrared light at 800 nm or more. The sample shown by the blue line, however, is apparently not very transparent to near-infrared light.

    Chemicals

    Thickness Measurements of Cling Films

    Thickness Measurements of Cling Films

    Undulating interference waveforms sometimes occur if light is passed through a film. The film thickness of a sample can be determined by using these interference waveforms. The figure shows transmittance data for a cling film. A clear interference waveform is produced. Utilizing optional film thickness measurement software, the film thickness is calculated as 10.4 μm. (Caution) The sample's refractive index must be entered for the film thickness calculation.

    Textiles

    Total Transmittance Spectrum of CNF

    Total Transmittance Spectrum of CNF

    An ISR-2600Plus integrating sphere was used to measure the total transmittance spectrum of cellulose nanofiber (CNF). Depending on the raw materials used, spectra can vary, transparency can vary, and spectral tendencies in the ultraviolet region can vary.

    Life Sciences

    DNA and Protein Measurements

    The red and blue lines are the absorption spectra for dsDNA and BSA (bovine serum albumin), respectively.
    The concentration values are 45 ng/μL for dsDNA and 2.2 mg/mL for BSA.

    Foods

    Vitamin Measurements

    This shows the absorption spectra for riboflavin (vitamin B2).
    The sample concentrations are, in order from the highest absorbance, 0.08,
    0.04, 0.02, and 0.01 mg/mL.