0

    SALD-2300 - Specs

    Laser Diffraction Particle Size Analyzer

    SALD-2300

    General Specifications

    Measurement principle

    Laser Diffraction Method

    Measurement range

    17nm(0.017μm) to 2500μm

    Measurement range

    17nm(0.017μm) to 400μm

    Measurement range

    30nm(0.030μm) to 280μm

    Measurement range

    300nm(0.3μm) to 2500μm

    Note 1: The measurement range varies according to the shape etc. of the particle.

    Read more
    Show Less

    SALD-2300

    Measurement Unit: SALD-2300 (P/N: 347-61700-42[115V], 347-61700-44[230V])

    Light source

    Red Semiconductor laser (Wavelength 680 nm)

    Light detector

    Detector elements for UV semiconductor laser
    Total 84 elements (78 forward, 1 side, 5 back)

    System Compliance

    Class 1 Laser Product, CE compliant

    Required power supply

    115 or 230 VAC as ordered 100 VA

    Dimensions & weight

    W680mm×D280mm×H430mm, 31kg

    Operating Environment

    Temperature: 10 to 30°C, Humidity: 20 to 80 % (no condensation)

    Note 2: Reference sample and USB cable (2 m) supplied as standard

    Read more
    Show Less

    SALD-MS23

    Sampler: SALD-MS23 (P/N: 347-61701-42[115V], 347-61701-44[230V])

    Dispersing bath

    Capacity: 100~280cm3

    Sonicator

    Frequency about 32 kHz, output about 40 W

    Liquid Pump

    Radial pump, maximum flow rate 2000cm3/min

    Liquid Pump Material

    Stainless (SUS 304, SUS 316), Tetrafluoroethylene (PTFE), Perfluoroelastmor (FEP) or Kalrez, Thermoflon Pascal (inside)

    Liquid Supply Pump

    Diaphragm pump, maximum flow rate 750cm3/min

    Liquid Supply Pump Material

    Tetrafluoroethylene, polyvinyl dene fluoride

    Flow Cell

    Quartz glass

    Required power supply

    115 or 230 VAC as ordered, 200 VA

    Dimensions & weight

    W390mm×D520mm×H430mm,18kg

    Operating Environment

    Temperature: 10 to 30°C, Humidity: 20 to 80 % (no condensation)

    Note 3: USB cable (2 m) supplied as standard

    Read more
    Show Less

    SALD-HC23

    High-concentration Sample Measurement System: SALD-HC23 (P/N: 347-61703-42)

    Cell Material

    Borosilicate glass

    Required Liquid Volume

    Approx. 0.15 cm3

    Dimensions & weight

    W20mm×D100mm×H9mm, 0.2kg

    Operating Environment

    Temperature: 10 to 30°C, Humidity: 20 to 80 % (no condensation)

    Read more
    Show Less

    SALD-DS5

    Cyclone Injection Type Dry Measurement Unit: SALD-DS5 (P/N: 347-61706-42[115V], 347-61706-44[230V])

    Sample suction types

    Cyclone type / One shot type / Hand shot type

    Suction nozzle

    Can be selected from 3 types

    SALD-DS5

    Cyclone Injection Type Dry Measurement Unit: SALD-DS5 (P/N: 347-61706-42[115V], 347-61706-44[230V])

    System

    Cyclone type

    Communication method

    USB (PC control)

    Required power supply

    115/230VAC(±10%), 100VA, 50/60Hz (excluding dust collector and compressor)

    Dimensions & weight

    W 240×D 310×H 210 mm, 10 kg

    Operating Environment

    Temperature: 10 to 30°C, Humidity: 20 to 80 % (no condensation)

    Read more
    Show Less

    SALD-DS5

    Cyclone Injection Type Dry Measurement Unit: SALD-DS5 (P/N: 347-61706-42[115V], 347-61706-44[230V])

    Primary pressure

    0.6 to 0.8 MPa

    Secondary pressure

    0.05 to 0.5 MPa

    Filtration rating

    Removing particles of 5 μm or larger

    Connection to air source

    Tube of 6 mm outside diameter

    Communication method

    USB (PC control)

    Required power supply

    115/230VAC(±10%), 100VA, 50/60Hz (excluding dust collector and compressor)

    Dimensions & weight

    W 130×D 223×H 233 mm, 3 kg

    Operating Environment

    Temperature: 10 to 30°C, Humidity: 20 to 80 % (no condensation)

    Read more
    Show Less

    Compressor: Output

    0.4 kW

    Compressor: Minimum pressure

    Approx. 7 kgf/cm2 (approx. 0.69 MPa)

    Compressor: Air discharge

    45 L/min

    Compressor: Tank volume

    Approx. 30 L

    Dust collector: Type

    Vacuum cleaner (Paper pack type)

    Dust collector: Dust collecting efficiency

    More than 99% for 0.3 μm particles

    Dust collector: Capacity

    2.0 m3/min or more

    Dust collector: Vacuum

    Approx. 2000 mm Aq or lower

    Dust collector: Suction hose diameter

    Approx. 32 mm

    Read more
    Show Less

    WingSALD II

    Measurement and Data Display Functions

    Measurement of Particle Size Distribution

    Allows measurements using measurement assistant function (interactive process based on SOP)

    Refractive Index Setting

    Automatic refractive index calculation function (LDR method: Light Intensity Distribution Reproduction Method) makes setting the refractive index easy.

    Real-Time Display

    Particle size distribution/light intensity distribution simultaneous display

    Diagnostics/Adjustments

    Self-diagnostic function and cell check function

    Recalculation of Particle Size Distribution

    Batch recalculation of max. 200 distributions

    Display of Particle Size Distribution Data

    Displays overlay of max. 200 distributions

    Display of Light Intensity Distribution

    Displays overlay of max. 200 distributions

    Statistical Data Processing

    Max. 200 sets of data (also allows overlaying max. 200 data sets)

    Time-Series Processing

    Max. 200 sets of data

    3-Dimensional Graphing

    Max. 200 sets of data

    Data Transfer via Clipboard

    [Image Output]: Outputs entire data sheet or graph only.
    [Text Output]: Outputs summary data, particle size distribution data, or light intensity distribution data.

    Data Sorting

    Sorts by file name, sample ID, sample number, or refractive index

    Read more
    Show Less

    WingSALD II

    Output Conditions

    Particle Size (μm) Divisions

    Fixed 51 or 101 divisions    : User settable 51 divisions

    Particle Amount (%) Divisions

    Fixed 51 divisions : User settable 51 divisions

    Distribution Basis

    Count, length, area, or volume

    Expression of Cumulative Distribution

    Oversized or undersized

    Expression of Frequency Distribution

    q, q / Δ×, q / Δlog ×

    Smoothing Levels

    10 levels

    Distribution Function Fitting

    Rosin-Rammler distribution, logarithmic Gaussian distribution

    Data Shifting

    ±10 levels

    Report Function

    Single data sets, overlaid data, statistical data, time-series data, or 3D data can be selected and output using batch processing

    Read more
    Show Less

    WingSALD II

    Data Analysis Functions

    Scattering Angle Evaluation Function

    Evaluates scattering characteristics within micro angle regions for samples such as optical films and sheets.

    Data Emulation Functions

    Emulates measurement results from other instruments and measurement principles, using SALD series measurement results.

    Mixture Data Simulation Function

    Simulates particle size distributions using any mixture ratio of multiple particle size distributions.

    Data Connection Function

    Combines two particle size distributions with different measurement ranges at any particle size point to create a single particle size distribution.

    Continuous Measurement Function

    Continuously measures changes in particle size distributions and particle diameters over time, at intervals as short as one second, and saves the results.

    Note 4:The LDR method automatically calculates an appropriate refractive index based on consistency between the actual measured light intensity distribution and one reproduced (recalculated) from particle size distribution data. This method was developed by Shimadzu and published in two technical papers. It is sometimes called the "Kinoshita Method", in academic communities, after the name of Shimadzu’s engineer.

    Read more
    Show Less

    SALD-2300

    Measurement Unit: SALD-2300 (P/N: 347-61700-42[115V], 347-61700-44[230V])

    Measurement range

    17 nm to 2,500 µm

    Light source

    Red semiconductor laser

    Detection elements

    84 elements

    Options

    Multifunctional variable-volume sampler, batch cell, highconcentration sample measurement system, cyclone injection type dry measurement unit

    Read more
    Show Less

    SALD-BC23

    Batch Cell: SALD-BC23 (P/N: 347-61702-42)

    Cell Material

    Quartz glass

    Required Liquid Volume

    Approx. 12 cm3

    Stirrer Mechanism

    Up-and-down movement of blade

    Dimensions & weight

    W100mm×D120mm×H140mm, 0.8kg

    Operating Environment

    Temperature: 10 to 30°C, Humidity: 20 to 80 % (no condensation)

    Read more