    Seamless control of Shimadzu LC

    Product

    Description
    Shimadzu LC Driver for Chromeleon™ 7 (for 1 system)

    Compatible ROM Versions

    Shimadzu LC Driver Ver. 3.20 Compatible with Chromeleon™ 7 supports the units with the following ROM versions. Update the ROM if necessary.

     

    1) Nexera/Prominence

    Unit Model Minimum required
    ROM version
    System Controller CBM-20A, CBM-20Alite 3.70
    Pump LC-30AD 3.21
    LC-20ADXR 2.12
    LC-20AD 2.11
    LC-20AT 2.01
    LC-20Ai 1.01
    LC-20AB 2.02
    Column Oven CTO-30AS 3.10
    CTO-30A 3.11
    CTO-20A / CTO-20AC 2.10
    Autosampler SIL-30ACMP 3.21
    SIL-30AC 3.22
    SIL-20A (HT, UFLC), SIL-20AC (HT, UFLC),
    SIL-20AXR, SIL-20ACXR
    Old board: 1.31
    New board: 2.12
    Rack Changer II 2.00
    Rack Changer, Rack Changer C 1.11
    Subcontroller Subcontroller VP (Option Box VP) 5.22
    Detector SPD-M30A 4.04
    SPD-M20A 2.03
    SPD-20A, SPD-20AV Old board: 2.03​
    New board: 3.03
    RF-20A, RF-20AXS 2.02
    RID-20A Old board: 1.04​
    New board: 2.04​
    Analog input board (PC-55N) -

    Note: For Chromeleon 7 compatible Shimadzu LC driver Ver. 2.01 and later, authentication setting on the instrument is required during the installation of the driver. Check the compatible ROM versions of the CBM- 20A/lite and configure settings for the instrument connection key. 

    2) i-Series (for LC-2030/2040/2030 Plus/2040 Plus)

     

    Unit Model Minimum required
    ROM version
    i-Series Unable to connect *1
    i-Series Plus LC-2030 Plus,LC-2030C Plus,LC-2030C 3D Plus
    LC-2040C Plus,LC-2040C 3D Plus
    LC-2030C LT Plus
    LC-2040C MT Plus,LC-2040C 3D MT Plus
    3.02
    External Detector RF-20A, RF-20AXS 2.02
    RID-20A Old board: 1.04​
    New board: 2.04​

    Note: For Chromeleon 7 compatible Shimadzu LC driver Ver. 2.01 and later, authentication setting on the instrument is required during the installation of the driver. Check the compatible ROM versions of the i-Series and configure settings for the instrument connection key.

    *1 When using i-Series LC-2030/LC-2040 (non-Plus models), do not update the Chromeleon LC driver to version 3.20.

     

    3) i-Series LC-2050/LC-2060

     

    Unit Model Minimum required ROM version
    i-Series
    LC-2050/LC-2060
    LC-2050,LC-2050C,LC-2050C 3D
    LC-2050C LT
    LC-2060C,LC-2060C 3D
    LC-2060C 3D MT
    3.20
    Mobile Phase Monitor MPM-40 1.04
    External Detector SPD-M40 2.01
    RF-20A, RF-20AXS 2.02
    RID-20A Old board: 1.04​
    New board: 2.04​

    Note: i-Series LC-2050/LC-2060 driver does not need the instrument connection key.

     

    4) Nexera series

    Unit Model Minimum required
    ROM version
    System Controller SCL-40, CBM-40, CBM-40lite 1.20
    Pump LC-40D, LC-40D XR, LC-40B XR 1.02
    LC-40D XS, LC-40D X3, LC-40B X3 1.02
    LC-40D XSi 1.07(*1)
    LC-40i 1.00(*2)
    LC-20AB (including LC-Mikros in LC-20AB compatible
    mode)
    2.02
    Column Oven CTO-40C 1.00
    CTO-40S 1.00
      CTO-30A 3.11
    Chemical reaction box CRB-40 2.00(*3)
    Autosampler
    SIL-20A, SIL-20AC Old board: 1.32
    New board: 2.13
    SIL-30ACMP 3.21
    SIL-40, SIL-40C, SIL-40 XR, SIL-40C XR
    SIL-40C XS, SIL-40C X3
    1.05(*4)
    SIL-40C XSi 1.10(*1) (*4)
    Plate Changer 1.04(*4)
    Detector SPD-40, SPD-40V 1.02
    SPD-M40 2.01
    SPD-M30A 4.04
    RF-20A, RF-20AXS 2.02
    CDD-10Avp 5.10
    RID-20A Old board: 1.04
    New board: 2.04
    Optional board -
    Mobile Phase Monitor MPM-40 1.02
    Mobile Phase Flow Line
    Switching Valve
    LPGE Unit, FCV-11AL, FCV-11ALS
    UV recycle valve
    -
    High-Pressure Flow Line
    Switching Valve
     
    FCV-0206, FCV-0607, FCV-0206H
    FCV-0607H, FCV-0206H3, FCV-0607H3,
    FCV-0206H2i, FCV-0607H2i,
    FCV-36AH
    -
    FCV-BOX, FCV-S -
    FCV-DR 1.02
    • *1 To control this instrument, it is necessary to update the ROM version of the system controller to 1.60 or later.
    • *2 To control this instrument, it is necessary to update the ROM version of the system controller to 1.62 or later.
    • *3 To control this instrument, it is necessary to update the ROM version of the system controller to 1.43 or later.
    • *4 When updated ROM version of Autosampler to 1.08 or later, please update the ROM version of Plate Changer to 1.08 or later too.

     Note:

    The [Nexera series] driver does not support other models such as LC-30AD.