Q.Please tell me the precautions to follow when using and storing weights.

  LCMS-8060NX LCMS-8060 LCMS-8050 LCMS-8045 LCMS-8040
Features On top of the architecture of the LCMS-8060, it adds flexibility in optimizing parameters to achieve unsurpassed sensitivity. New ion optic components all increase robustness without compromising on a high ion transmission rate. A new vision in sensitivity. It is suitable for drug discovery, manufacturing, clinical research, food safety, environmental, or drugs-of-abuse analysis. The first mass spectrometer to achieve a scan speed of 30,000 u/sec and 5 msec polarity switching time. It boasts the ideal balance of good data quality, high throughput and affordability for a wide range of challenging and routine applications. Designed specially for robust data acquisition with best-in-class sensitivity. It withstands long periods of continuous operation in laboratories in demand of reliable data. Introduces the new UF-Lens™ and UFsweeper™ II, the hallmark technologies underlying fast ion transmission and high sensitivity.
Sensitivity (S/N) ●●●●● ●●●●● ●●●● ●●● ●●
Scan Speed ●●●●● ●●●●● ●●●●● ●●●●● ●●●
  LCMS-8060NX LCMS-8060 LCMS-8050 LCMS-8045 LCMS-8040
Features On top of the architecture of the LCMS-8060, it adds flexibility in optimizing parameters to achieve unsurpassed sensitivity. New ion optic components all increase robustness without compromising on a high ion transmission rate. A new vision in sensitivity. It is suitable for drug discovery, manufacturing, clinical research, food safety, environmental, or drugs-of-abuse analysis. The first mass spectrometer to achieve a scan speed of 30,000 u/sec and 5 msec polarity switching time. It boasts the ideal balance of good data quality, high throughput and affordability for a wide range of challenging and routine applications. Designed specially for robust data acquisition with best-in-class sensitivity. It withstands long periods of continuous operation in laboratories in demand of reliable data. Introduces the new UF-Lens™ and UFsweeper™ II, the hallmark technologies underlying fast ion transmission and high sensitivity.
Sensitivity (S/N) ●●●● ●●●● ●●●● ●●● ●●
Scan Speed ●●●● ●●●● ●●●● ●●●● ●●
Ionization Unit Compatibility ESI        
sample
APCI
sample
sample
sample
sample
sample
DUIS*1)
sample
sample
sample
sample
sample
Heated-ESI
sample
sample
sample
sample
 
Heated-ESI with IonFocus
sample
       
Micro-ESI
sample
sample
sample
sample
 
Probe-ESI
sample
sample
sample
sample
sample
Measurement Mode Q1 Scan/SIM
sample
sample
sample
sample
sample
Q3 Scan/SIM
sample
sample
sample
sample
sample
MRM
sample
sample
sample
sample
sample
Precursor ion scan
sample
sample
sample
sample
sample
Product ion scan
sample
sample
sample
sample
sample
Neutral loss scan
sample
sample
sample
sample
sample
Synchronized Survey Scan™*2)
sample
sample
sample
sample
sample
Collision Cell UFsweeper III*3) UFsweeper III*3) UFsweeper III*3) UFsweeper II*3) UFsweeper II*3)
  LCMS-8060NX LCMS-8060 LCMS-8050 LCMS-8045 LCMS-8040