Standard Specifications
Pump Main Unit
Turbo molecular pump | TMP-4304LMC | |
---|---|---|
Inlet flange | VG350 | |
Outlet flange | KF40 | |
Cooling method | Water | |
Ultimate pressure (after baking) | 10-7 Pa order | |
Maximum allowable Argon gas flow rate | 2200 mL/min (Note 1) | |
Maximum allowable inlet pressure | 40 Pa | |
Maximum allowable outlet pressure | 270 Pa | |
Pumping speed (Note 2) |
N2 | 4400 L/s |
Ar | 4200 L/s | |
H2 | 2600 L/s | |
Compression ratio | N2 | 1×109 or more |
He | 3×104 | |
H2 | 2×103 | |
Rated speed | 24000 rpm | |
Start-up time | 18 minutes or less | |
Mounting position | In any desired direction | |
Vibration level (by Shimadzu's method) | 0.01 µm or less (0-peak) | |
Recommended flow rate of purge gas | 30 mL/min (Note 1) | |
Recommended pumping speed of backing pump in case of gas purge |
1500 L/min or more | |
Environmental Temperatures | 0 to 40 degrees C. | |
Admissible ambient magnetic field |
Radial direction | 3 mT |
Axial direction | 15 mT | |
Water | Flow rate | 2 to 4 L/min |
Pressure | 0.2 to 0.5 MPa | |
Temperature | 5 to 25 degrees C. | |
Mass | 105 kg |
Power Supply Unit
Power supply unit | EI-R04M | |||||||
---|---|---|---|---|---|---|---|---|
Battery | Not Necessary | |||||||
Exchangeable compatibility | The control cable is interchangeable between any pump and power supply unit. | |||||||
Speed variation | Speed is variable between 25 % and 100 % of the rated speed. (set as 0.1 %) | |||||||
Communication | Contact | REMOTE (MR-34)
|
||||||
Serial |
|
|||||||
Environmental conditions | Temperature | Operation 0 to 45 degrees C. (No dew condensation) | ||||||
Relative humidity | 40 to 80 %RH | |||||||
Input electric power | Voltage | Single phase 200 to 240 VAC ± 10 % (50/60 Hz ± 2 Hz) | ||||||
Maximum power | 1.5 kVA | |||||||
Mass | 8 kg |