Last update: May 9, 2022 GMT

■ Measurable Wavelength Range According to the Cell Material
Silica (S cell): 190 to 2500 nm, glass (G cell): 320 to 2500 nm, silica (IR cell): 230 to 3200 nm
The optical path length of the cells is 10 mm unless otherwise specified.
Cells common for all models (except for BioSpec-mini and BioSpec-nano)
Name P/N Appearance Qty Material Remarks
Rectangular cells 200-34442 1 Silica (S cell)
Rectangular cells 200-34442-50 10 Silica (S cell)
Rectangular cells 200-34442-60 20 Silica (S cell)
Rectangular cells 208-92296 1 Glass (G cell) When a cap is required, the cap (200-34565-02) should be purchased.
Rectangular cells 200-66579-01 1 Silica (IR cell)
Cells with stopper 200-34444 1 Silica (S cell) With a frosted glass cap
Cells with stopper 200-34444-01 1 Glass (G cell) With a frosted glass cap
Cells with stopper 200-66579-21 1 Silica (IR cell) With a frosted glass cap
Semi-micro cell 200-66501 1 Silica (S cell) Cell holder (204-06896) is required.
For the UVmini-1240/1240V and UV-1280, the sample compartment unit (206-60184-07) is also required.
Semi-micro cell 200-66501-01 1 Glass (G cell) Cell holder (204-06896) is required.
For the UVmini-1240/1240V and UV-1280, the sample compartment unit (206-60184-07) is also required.
Semi-micro cell 200-66579-11 1 Silica (IR cell) Cell holder (204-06896) is required.
For the UVmini-1240/1240V and UV-1280, the sample compartment unit (206-60184-07) is also required.
Semi-micro black cell 200-66551 1 Silica (S cell) With a 5 nm slit, the cell holder (P/N 204-06896) is required.
For the UVmini-1240/1240V and UV-1280, the sample compartment unit (206-60184-07) is also required.
Micro black cell 200-66578-12 1 Silica (S cell) ・One of the cell holders below is required.
206-14334-01 (UVmini-1240/1240V, UV-1280),
206-14334 (UV-1800/1900 Series)
For the UVmini-1240/1240V and UV-1280, the sample compartment unit (206-60184-07) is also required.
Also, the minimum required sample volume is 100 μL.
Supermicro black cell 200-66578-11 1 Silica (S cell) ・ For models other than BioSpec-1600, a cell holder is required.
206-14334-01 (UVmini-1240/1240V, UV-1280),
206-14334 (UV-1800/1900 Series)
For the UVmini-1240/1240V and UV-1280, the sample compartment unit (206-60184-07) is also required.
Also, the minimum required sample volume is 100 μL.
Cells with stopper (for BioSpec-nano)
P/N Qty Remarks Applicable model Links Applicable models
1 This horizontal cell with a stopper has an optical path length of 5 mm.
The adopter for 5 mm cells (206-26513) is required.
Sample volume: 2 mL
BioSpec-nano

Supplementary keywords: UV, UV-VIS spectrophotometer, spectrophotometer, spectrometer, cell, micro, black, life, bioscience, protein