The method specifies isocratic conditions using a Shim-pack Scepter™ C18-120 metal-free column and a methanol and 0.01 mol/L ammonium as the mobile phase. It can separate three types of mercury compounds: divalent mercury, methylmercury, and ethylmercury.
LC-ICP-MS
The ICPMS-2040/2050 can be combined with the Nexera inert series or the Prominence inert analysis system to form an LC-ICP-MS system.
-
-
This method is for gradient elution using an anion exchange column, 0.025 mol/L ammonium dihydrogen phosphate solution as mobile phase A, and water as mobile phase B. It can separate arsenocholine (AsC), arsenobetaine (AsB), arsenic trioxide (As3+), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), and arsenic (As5+) forms of arsenic.
-
This method uses formic acid as the mobile phase. It can separate six types of arsenic compounds: arsenic (As5+), arsenic trioxide (As3+), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC).
News / Events
-
What is ICP-MS (Inductively Coupled Plasma Mass Spectrometry)?
Basics of Inductively Coupled Plasma Mass Spectrometry is now available.
-
Three Analytical and Measuring Instruments Win the Internationally Recognized “iF Design Award 2024”
The Shimadzu LCMS-2050 high-performance liquid chromatograph mass spectrometer, the Brevis GC-2050 gas chromatograph, and the ICPMS-2040/2050 ICP mass spectrometer won the internationally recognized iF Design Award 2024 in the product design category.
-
New Video: The Cabbage Core, Trash or Treasure?
Most people throw out the cabbage core when cooking, but is the core really just trash or actually a hidden treasure of nutrients?
-
New Video: ICPMS-2040/2050 Extended Rinsing
The extended rinsing function automatically performs an additional rinse sequence when a target element exceeds a predetermined upper limit. A second rinse solution can be used in the additional rinsing sequence to improve rinsing effectiveness. Consequently, carryover is eliminated to ensure high-quality data.
-
New Video: ICPMS-2040/2050 ProActive Rinsing
ProActive Rinsing can shorten the analysis time by sharting the rinsing sequence in advance. While measuring multiple samples, the rinsing sequence can be started early by sending the autosampler probe to rinse while collecting data using sample already in the suction line. This greatly reduces measurement time and conserves sample.
-
Shimadzu has released the ICPMS-2040 Series / ICPMS-2050 Series, Inductively Coupled Plasma Mass Spectrometry
ICPMS-2040/ 2050 Series has achieved a harmonious blend of environmental-friendliness and analytical performance.