    Triple quadrupole mass spectrometry (TQMS) is a versatile tool for quantitative analysis. Experience the excellent performance and robustness of Shimadzu’s LCMS-TQ instruments, which offer a choice of speed, sensitivity and resolution to meet the demands of high-throughput routine analysis and/or more specialized applications. 

    Compare Shimadzu’s triple quadrupole LC-MS/MS systems below. 

     

    Triple Quadrupole LC-MS/MS Comparison

      LCMS-8060RX LCMS-8050RX LCMS-8045RX
    Features The LCMS-8060RX builds on the exceptional sensitivity and UF capabilities of the LCMS-8060NX and adds even more robustness without compromising sensitivity. Engineered to deliver excellent sensitivity the LCMS-8050RX further extends the performance of the LCMS-8050 to meet the ever-changing needs of any LC-MS/MS laboratory. Designed for rugged, routine LC-MS/MS analysis with the optimal balance of cost, sensitivity and performance now enhanced with greater robustness and easier to use.
    Sensitivity (S/N) 5 4 3
    Scan Speed 5 5 5
    Ionization Unit Compatibility ESI      
    APCI
    sample
    sample
    sample
    DUIS*1)
    sample
    sample
    sample
    Heated-ESI
    sample
    sample
    sample
    Heated-ESI with IonFocus
    sample
    sample
    sample
    Micro-ESI
    sample
    sample
    sample
    Probe-ESI
    sample
    sample
    sample
    Measurement Mode Q1 Scan/SIM
    sample
    sample
    sample
    Q3 Scan/SIM
    sample
    sample
    sample
    MRM
    sample
    sample
    sample
    Precursor ion scan
    sample
    sample
    sample
    Product ion scan
    sample
    sample
    sample
    Neutral loss scan
    sample
    sample
    sample
    Synchronized Survey Scan™*2)
    sample
    sample
    sample
    Collision Cell UFsweeper™*3) III UFsweeper III UFsweeper II
    QP guard *4)
    sample
       
      LCMS-8060RX LCMS-8050RX LCMS-8045RX
    • DUIS: The dual ion source continuously performs both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI).
    • Synchronized Survey Scan: Synchronized Survey Scan (SSS) automatically performs a product ion scanning whenever a pre-set survey scan threshold is exceeded.
    • UFsweeper: UFsweeper is a unique technology that delivers unparalleled efficiency and speed. UFsweeper accelerates ions out of the collision cell by forming a pseudo-potential surface.
    • QP guard: Reduces contamination of the quadrupole rod by applying voltage to the multi-pole and preventing unwanted ions from entering the quadrupole rod.