Nexera Prep - Specs

Preparative Purification Liquid Chromatograph

Excellent System Expandability

Solvent Delivery Unit Accommodates a Wide Range of Recovery Volumes

Guidelines for Preparative Scale and Maximum Load

Guidelines for Preparative Scale and Maximum Load

The figure at right shows the guidelines for total component capacity with a 250 mm long column when the target component is highly soluble in the mobile phase, separates from impurities, and ions are suppressed. For isocratic elution, in principle, the total component capacity is proportional to the column volume.

LC-40D
Supports a Range of Applications from High-Precision Analytical to Semi-Preparative

LC-40D

LC-40D

  • This solvent delivery unit can handle flow rates ranging from those used in analytical scale to those used in semi-preparative (up to 10 mL/min).
  • High-precision analysis is possible even in the semi-micro flow-rate range.

LC-20AR
Supports Semi-Preparative and Recycle Preparative

LC-AR

LC-20AR

  • This solvent delivery unit can handle flow rates used in semi-preparative scale (up to 20 mL/min).
  • Using a recycle kit enables semi-preparative recycling.

LC-20AP
Supports Large-Scale Preparative Fractionation

LC-20AP

LC-20AP

  • High flow rates (up to 150 mL/min) enable highly efficient, large-scale preparative fractionation.
  • Large-scale prep solvent delivery fully supports the preparative fractionation workflow, including reinjection, to assess purity.
  • Combine with an FCV-200AL low-pressure gradient unit to perform gradient analysis using up to four mobile phases.
Specifications
  LC-40D LC-20AR LC-20AP
Solvent Delivery Method Parallel-type double plunger
Plunger Capacity 10 μL 47 μL 250 μL
Maximum Discharge Pressure 44 MPa 49 MPa 42 MPa
Flow Rate Setting Range 0.0001 to 5.0000 mL/min (1.0 to 44 MPa)
5.0001 to 10.0000 mL/min (1.0 to 22 MPa)
0.01 to 20.00 mL/min 0.01 to 150.00 mL/min
Flow Rate Accuracy No more than ±1% or ±2 μL/min, whichever
is greater (under specified conditions)
No more than ±1% or ±10 μL/min,
whichever is greater (0.1 to 5.0 mL/min
No more than ±1% (1 mL/min, 10 MPa)
Flow Rate Precision No more than 0.06% RSD or 0.02 min SD, whichever is greater No more than 0.08% RSD or 0.02 min SD, whichever is greater No more than 0.1% RSD or 0.02 min SD, whichever is greater
Constant Pressure Solvent Delivery Supported
Plunger Rinsing Mechanism Optional available Syringe or rinsing pump (228-39625-41) Syringe or rinsing pump (228-39625-41)
Operating Temperature Range 4 to 35°C
Size and Weight W260 × H140 × D500 mm, 10 kg W260 × H140 × D500 mm, 16 kg W260 × H210 × D500 mm, 19 kg

LC-40D

LC-40D

LC-40D

• This solvent delivery unit can handle flow rates ranging from those used in analytical scale to those used in semi-preparative (up to 10 mL/min).
• High-precision analysis is possible even in the semi-micro flow-rate range.

Guidelines for Preparative Scale and Maximum Load

Solvent delivery method

Parallel-type double plunger

Plunger capacity

10 μL

Maximum discharge pressure

44 MPa

Flow rate setting range

0.0001 to 5.0000 mL/min (1.0 to 44 MPa)
5.0001 to 10.0000 mL/min (1.0 to 22 MPa)

Flow rate accuracy

No more than ±1% or ±2 μL/min, whichever
is greater (under specified conditions)

Flow rate precision

No more than 0.06% RSD or 0.02 min SD, whichever is greater

Constant pressure solvent delivery

Supported

Plunger rinsing mechanism

Optional available

Operating temperature range

4 to 35 °C

Size and weight

W260 × D500 × H140 mm, 10 kg

Read more
Show Less

LC-20AR

7 - Nexera Prep

This solvent delivery unit can handle flow rates used in semi-preparative scale (up to 20 mL/min).
Using a recycle kit enables semi-preparative recycling.

Supports Semi-Preparative and Recycle Preparative

Solvent delivery method

Parallel-type double plunger

Plunger capacity

47 μL

Maximum discharge pressure

49 Mpa

Flow rate setting range

0.001 to 20.000 mL/min

Flow rate accuracy

No more than ±1% or ±10 μL/min,whichever is greater (0.1 to 5.0 mL/min)

Flow rate precision

No more than 0.08% RSD or 0.02 min SD, whichever is greater

Constant pressure solvent delivery

Supported

Plunger rinsing mechanism

Syringe or rinsing pump

Operating temperature range

4 to 35 °C

Size and weight

W 260 x H140 x D 500 mm,16 kg

Read more
Show Less

LC-20AP

7 - Nexera Prep

High flow rates (up to 150 mL/min) enable highly efficient, large-scale preparative fractionation.
Large-scale prep solvent delivery fully supports the preparative fractionation workflow including reinjection to assess purity.
Combine with an FCV-200AL low-pressure gradient unit to perform gradient analysis using up to four mobile phases.

Supports Large-Scale Preparative Fractionation

Solvent delivery method

Parallel-type double plunger

Plunger capacity

250 μL

Maximum discharge pressure

42 Mpa

Flow rate setting range

0.01 to 150.00 mL/min

Flow rate accuracy

No more than ±1% (1 mL/min, 10 MPa)

Flow rate precision

No more than 0.1% RSD or 0.02 min SD,whichever is greater

Constant pressure solvent delivery

Supported

Plunger rinsing mechanism

Syringe or rinsing pump

Operating temperature range

4 to 35 °C

Size and weight

W 260 x H210 x D 500 mm,19 kg

Read more
Show Less

Shim-pack Scepter Columns

- Excellent stability & performance using a wide range of LC conditions -

Shim-pack Scepter LC columns, which are the next generation organic silica hybrid based columns, are designed for stability and performance in a wide range of mobile phase conditions. With different chemistry characteristics, Shim-pack Scepter columns are effective for method development/scouting under conditions that may compromise traditional silica based columns.
With different particle sizes (1.9 μm, 3 μm, 5 μm) and different column dimensions, Shim-pack Scepter LC columns are fully scalable between UHPLC, HPLC and preparative LC, making method transfer seamless between different laboratory instrumentation.

Shim-pack Scepter Reversed Phase
C18 HD-C18 C8 Phenyl PFPP
Functional Group Trifunctional C18 Trifunctional C18 Trifunctional C8 Trifunctional
Phenylbutyl
Trifunctional
Pentafluorophenylpropyl
Generic Purpose Type High Density Type
Particle Organic Silica Hybrid
Particle Size 1.9 μm,3 μm,5 μm
Pore Size 12 nm 8 nm 12 nm
End Capping Proprietary None
pH Range 1 - 12 1 - 10 1 - 8
100% Aqueous Condition Yes No No Yes Yes
USP Classification L1 L1 L7 L11 L43
{"title":"Specification Sheet Downloads","description":"Download the latest specification sheets.","source":"product","key":3107,"max":30,"filter_types":["spec_sheet"],"link_title":"View other Downloads","link_url":""} {"title":"Downloads","description":"Download the latest brochure.","source":"product","key":3107,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]}