LabSolutions™ ICPMS Ver. 2
Perform instrument control and data processing for the ICPMS-2040/2050 using LabSolutions ICPMS Version 2. The new version of LabSolutions ICPMS software displays all necessary information in a single window, simplifying operation for new users.
With all the necessary information displayed in a single window
Analysis Window
The customizable analysis window can simultaneously display the current sample profile, registered samples, analytical results, errors, and instrument status. The analysis progress can be monitored at a glance. Windows can be configured and customized based on the user's preference. The assistant bar along the left side guides the users through every step of analysis in the correct order.
Instrument Status Window
The instrument status window displays various information about the instrument and accessories in a comprehensive and easy-to-understand layout. A warning indicator is displayed if an error occurs or if a part is due for maintenance or replacement.
Automatic Internal Standard Monitoring
Internal standard fluctuation can be displayed as a graph for the entire analysis time, as either intensity or intensity ratio with respect to a reference sample. This helps quickly identify complications that occur due to sample matrix effects.
Simple and Descriptive Maintenance Window
The maintenance information/setting window in new LabSolutions™ ICPMS software clearly indicates operation times of key components and automatically alerts users when it is time to maintain and/or replace parts, taking the guesswork out of maintenance.
LabSolutions ICPMS TRM (Optional)
Shimadzu LC-ICP-MS systems combined with LabSolutions ICPMS TRM software can be used to speciate arsenic, mercury, and other elements. The software controls and configures both LC and ICPMS systems in one simple platform.
LabSolutions™ CS Suppor ts Laboratory Networking
Adding a LabSolutions™ DB/CS connection kit (optional) enables compliance with electronic recordkeeping and electronic signature regulations, such as requirements specified in FDA 21 CFR Part 11. Select either a standalone (LabSolutions DB) or networked (LabSolutions CS) system that is best for the given application. LabSolutions CS manages all analytical data in a database on a network server, so that the data can be loaded and postrun analysis can be performed on any computer connected to the network.
Note: An additional software license is required for loading data onto a computer not connected to an ICPMS-2040/2050 Series system.
*1 The acquisition control PC controls analytical instruments. It can also be used to send analytical instructions and perform postrun analysis, just like a client PC.
*2 If a terminal service is used, then LabSolutions software does not need to be installed on client PCs.
*3 If an iPad is used, then XenApp from Citrix must be installed.
News / Events
-
What is ICP-MS (Inductively Coupled Plasma Mass Spectrometry)?
Basics of Inductively Coupled Plasma Mass Spectrometry is now available.
-
Three Analytical and Measuring Instruments Win the Internationally Recognized “iF Design Award 2024”
The Shimadzu LCMS-2050 high-performance liquid chromatograph mass spectrometer, the Brevis GC-2050 gas chromatograph, and the ICPMS-2040/2050 ICP mass spectrometer won the internationally recognized iF Design Award 2024 in the product design category.
-
New Video: The Cabbage Core, Trash or Treasure?
Most people throw out the cabbage core when cooking, but is the core really just trash or actually a hidden treasure of nutrients?
-
New Video: ICPMS-2040/2050 Extended Rinsing
The extended rinsing function automatically performs an additional rinse sequence when a target element exceeds a predetermined upper limit. A second rinse solution can be used in the additional rinsing sequence to improve rinsing effectiveness. Consequently, carryover is eliminated to ensure high-quality data.
-
New Video: ICPMS-2040/2050 ProActive Rinsing
ProActive Rinsing can shorten the analysis time by sharting the rinsing sequence in advance. While measuring multiple samples, the rinsing sequence can be started early by sending the autosampler probe to rinse while collecting data using sample already in the suction line. This greatly reduces measurement time and conserves sample.
-
Shimadzu has released the ICPMS-2040 Series / ICPMS-2050 Series, Inductively Coupled Plasma Mass Spectrometry
ICPMS-2040/ 2050 Series has achieved a harmonious blend of environmental-friendliness and analytical performance.